Sponsored by...

Advertisement

Login

Donate to Code59!

Donations are used to maintain the web site, and on equipment and tools to continue code59 development. 100% of donations go back into the project and web site.

Code59 Initial TunerPro V5 ADX and XDF Files - Release 2/19/2010

************** 1.6_V25 XDF TP5 Only Revision History ***************
2/19/2010 - Paul
Intial TP5 XDF file based off the 1.6 TP4 file. 

** This is for TP5 Only ** 

 Code59 1.6_V25 TP5 Only XDF

Code59 .5 Beta TP5 Only ADX

************** 0.5 Beta TP Only ADX Revision History ***************
2/19/2010 - Paul

Initial BETA Release of TunerPro 5.0 ADX for Code59 Mask

Please post any errors you find and any suggestions for History, Monitors, Dashboard, etc you would like to see

Thanks to John (JP86SS on Thirdgen) and Jeff Scott (V8TTTY on SyTy) for Dashboard samples and ideas.

 
Code59 3Bar 1.6 V18 XDF RELEASED - 2/16/2010

Code59 3Bar 1.6 V18 DOWNLOAD

 ************** 1.6_V18 XDF Revision History ***************
2/16/2010 - Reved Release version to 1.6

************** 1.5_V18 XDF REV 5 Revision History ***************
8/14/2009 1project2many
Max Retard (Reference) (KMAXRTD2) (0026) - Fixed Formula change to 0.3515625 * X + 0.000000 from 2*X+0

7/21/2009 - Paul
Hi RPM Adv. Slope (KADVSLHI) (0010) - Changed units to DEG/1000 RPM from RPM
        - Changed Formula to 0.10986328125 * X + 0.000000 from 0.1 * X + 0.000000

7/14/2009 - RBob

Fixed Column lable error in F92 table.  It should be in uSec and not mSec.
Fixed Column lable error in F94 table.  It should be in uSec and not mSec.

7/9/2009 - j91z28d1n2o

Changed Road Speed IP Pulse Divisor (KSPDDIV) from a slider in the constant section to a Flag section
and added these notes for it.  These are the only valid settings for the Speedometer output for the
Dash.

BIT 7 6 5
    0 0 0 Divide by 1 (ie for a 4000 ppm VSS)
    0 0 1 Divide by 9 (36000 ppm VSS)
    0 1 0 Divide by 7 (28000 ppm VSS)
    0 1 1 Divide by 11 (44000 ppm VSS)
    1 0 0 Divide by 6 (24000 ppm VSS)
    1 0 1 Divide by 10 (40000 ppm VSS)
    1 1 0 Divide by 8 (32000 ppm VSS)
    1 1 1 Divisor disabled, no output

7/9/2009 - Paul
Changed XDF Item Desciption for
 RPM above which Quasi-Asynch Fuel **NOT USED** (KQASRPMD) to read as RPM above which Quasi-Asynch Fuel is NOT USED(KQASRPMD)
 Changed Number of Cylinders (00-8 C0-6 10-4 18-TBI) (KNUMCYL) to Number of Cylinders (See Description Notes) (KNUMCYL) and added notes for the different cylinder selections

Corrected Cylinder Select Codes and added to Item Description - (4 Cylinder was incorrect was listed as $10 when it should be $80)
 8 Cylinder - $00        3 Cylinder - $60
 6 Cylinder - $C0        TBI - $18
 4 Cylinder - $80


Changed the Last Column to 80MPH from 70MPH for the F70_mph and F71_mph tables to remove some confusion.
 F70_MPH 30 40 50 60 70 80 <- Will never reach the 80 MPH cells due to code limit
 F71_MPH 0 10 20 30 40 50 60 70 80 <- Will never reach the 80 MPH cells due to code limit
 Added the note that both of these tables will never reach the 80MPH setting and to make sure
 both cells in the 70 and 80 MPH are the same value.

 
Code59 e-mail registrations not working

If you're having issues getting registered, please check your spam filters for the confirmation mails from code59.org.  We're finding a lot of unconfirmed accounts.

 We're working on enabling the accounts that have registered, but there's a lot of them, as well as a lot of spammer accounts to clear out.

If you're sure you already registered, try requesting a password change.

 

Sorry about the issues... we hope to have these resolved soon.

 
<< Start < Prev 1 2 Next > End >>

Results 1 - 4 of 5

Latest Forum Topics


More...
© 2010 Code59
Joomla! is Free Software released under the GNU/GPL License.